Military wearable technology puts thin, printed electronics into the clothing and equipment service members already carry. The U.S. military is already testing and fielding wearables, so the engineering question has moved from “could this work” to “how do we validate, power, wash, and integrate it?”
This guide covers each application and the requirements that decide whether a prototype becomes fielded gear.
Quick answer: Five military wearable technology applications stand out today: heated clothing for cold-weather operations, health and heat strain monitoring, pressure mapping for boots, packs and body armor, rehabilitation support, and training performance monitoring. Each relies on sensors or heaters that flex with the body, withstand sweat and laundering, and add little weight.
What Are the 5 Military Applications for Wearable Technology?
The five applications with the clearest near-term value are heated clothing and gear, health and heat strain monitoring, load and fit pressure mapping, rehabilitation and recovery support, and training performance monitoring. All five rely on conductive inks printed on thin, flexible films, which is why they fit inside a glove, a boot, a compression shirt, or a plate carrier.


1. Heated Clothing and Gear: How Do Printed Heaters Help in Cold-Weather Operations?
Printed flexible heaters place a thin resistive circuit inside gloves, jackets, boot liners and sleep systems, warming the areas most exposed to cold injury. They replace wire elements with printed silver and carbon ink traces on film and run from a portable battery pack, so warmth is available without adding an insulating layer.
Cold injury remains common. From July 2023 through June 2024, 456 active and reserve component members had at least one cold weather injury, and soldiers had the highest active component rate at 52.6 per 100,000 person-years (MSMR, 2024). Frostbite was the most common type in the first three of the five seasons studied.
The heater type decides how temperature is controlled:
- Fixed resistance heaters use silver ink traces and bus bars printed on TPU. Resistance stays fixed, so a closed-loop controller must manage temperature. BTI lists maximums up to 80°C.
- PTC (positive temperature coefficient) heaters use silver traces and carbon ink tiles printed on PET. The carbon creates a temperature ceiling of 80°C. Only PTC heaters are self-limiting.
In clothing, skin-contact limits matter more than peaks. BTI’s guidance is to keep skin-contact heaters between 20 and 36°C and to insulate anything hotter than 43°C. Most flexible heaters are 0.05 to 0.76 mm thick and typically run from a 12 to 24 volt battery pack. For outdoor use cases, see our note on avoiding cold stress with heater technology.
Design trap: validating on a bench supply at room temperature. Test at worst-case cold and wind with the actual battery and connector, because voltage sag and contact resistance change the heat delivered.

2. Health and Heat Strain Monitoring: What Can Biometric Sensors Track in the Field?
Printed biometric sensors in compression garments record heart activity (ECG) and other bioelectric signals that algorithms combine with skin temperature and motion to estimate strain and readiness. The military priority is early warning, especially for heat illness, which caused 471 heat stroke cases in the U.S. active component in 2024.
The same report counted 2,380 heat exhaustion cases and a rise in heat stroke rates after declines from 2020 through 2023 (MSMR, 2025). Three current efforts show the direction:
- Heat Illness Prevention System (HIPS): USARIEM’s chest-worn system, in development since 2018, monitors heart rate, skin temperature, estimated core temperature, and gait stability, drawing on about 14,000 high-risk training events (USARIEM, 2024).
- Wearable All-hazard Remote-monitoring Program (WARP): JPEO-CBRND down-selected from nearly 400 devices to an on-body hub with more than 25 sensors. The first operational test took place in November 2024, with fielding slated for the start of fiscal year 2026 (U.S. Army, 2025).
- Optimizing the Human Weapon System (OHWS): Started as a COVID-19 screening effort, OHWS grew into a joint program. In 2024, the Army War College offered smartwatches and rings to more than 200 colonels and lieutenant colonels (USAMRDC, 2024).
A printed sensor supplies the skin interface in systems like these. BTI’s biometric sensors are dry electrodes (silver, silver chloride, carbon, or a proprietary blend) on stretchable TPU, so they need compression to stay in contact with skin. See which biometric signals printed sensors can measure and our earlier look at biometric feedback for military performance.
3. Load, Fit and Pressure Mapping: How Do Force Sensing Resistors Help Soldiers Carry Weight?
Force sensing resistors (FSRs) printed into insoles, pack straps, hip belts and body armor liners show where load concentrates and how it shifts during movement. Designers use that data to fit armor, balance packs, and study gait under load, a real concern when low back injuries cost the Army more than one million lost or limited duty days a year.
That figure comes from the Army Public Health Center, as cited by DEVCOM (2022). An FSR is a thin, layered variable resistor whose resistance changes with pressure. Two constructions matter:
- ShuntMode: silver interdigitated fingers shunted by a carbon layer. Wider force range, more linear output, usually lower cost. Good for insoles and pack loads.
- ThruMode: more responsive to light forces and fits smaller form factors. Good for contact pressure under an armor plate.
Read more in detail: ShuntMode vs. ThruMode Force Sensing Resistors
A single-zone sensor detects load in one area while a discrete array of sensors detects loads at multiple locations at one time such as the heel and balls of the feet. A Matrix array is typically used to detect loads in dozens of smaller areas with the output being a pressure map of the entire area. For example, an array of 10 column sensors and 16 row sensors provides 160 sensing points for the pressure map. The greater number of sensing points, the greater resolution of the pressure map. See force sensing resistors and a comparison of FSR design types.
Peer-reviewed work supports this. A 2023 Sensors study compared wireless in-shoe force sensors with an instrumented treadmill while Singapore Armed Forces personnel carried 25 and 35 kg, and found good agreement, though the sensors underestimated impact peak force on inclines (Kong et al., 2023).
Design trap: treating an FSR like a load cell. FSR output is nonlinear but repeatable, and less accurate than a load cell, so use it for distribution, timing and trends. Foam, soles and armor backing change the calibration, so design the load path with the sensor.

4. Rehabilitation and Recovery: Where Do Printed Electrodes Fit?
In rehabilitation, printed sEMG electrodes in a sleeve or compression garment let clinicians track muscle activation and left-right symmetry between sessions and outside the clinic. The same electrode platforms can serve as the skin interface for stimulation devices such as TENS or NMES. Still, the stimulator itself is a regulated medical device owned by the OEM.
BTI’s custom capabilities include a telemedicine biometric sleeve, produced with a design firm partner in 2022, whose stretchable conductive ink sensors monitor muscle activity remotely. That data shows whether an injured limb is regaining activation compared with the other side.
BTI’s biometric sensor page also lists electrode uses for EMS, TENS, and NMES. The electronics are a separate matter: FDA classifies a transcutaneous electrical nerve stimulator for pain relief as a Class II device under 21 CFR 882.5890, so the OEM owns the stimulator, its clinical claims, and its regulatory pathway. Claims that heat or stimulation speeds healing or builds muscle need clinical evidence for the finished device; they are not properties of a printed electrode.

5. Training and Performance Monitoring: What Should Instructors Measure?
Performance monitoring pairs heart rate and training load with muscle activity so instructors can balance hard and easy days, catch fatigue, and spot left-right asymmetry before it becomes an injury. Printed sEMG sensors add the muscle-level data that wrist-worn devices do not measure directly.
The Army’s MASTR-E effort, a five-year program started in October 2020, studies readiness across five constructs: shoot, move, sustain, navigate, and communicate. OHWS leaders describe using wearable data to “tailor high density days versus low density days” (Army Technology, 2023).
In 2016, BTI produced biometric athletic shorts with printed sEMG sensors that, per BTI’s case study, were used by professional athletes across the NFL, NBA, and MLS. Military training adds heavier loads, longer wear, and harder laundering.
What Design Requirements Decide Whether a Military Wearable Gets Fielded?
Fielded military wearables must deliver validated, actionable data or heat, survive sweat, abrasion, and laundering, run on a limited battery budget, and connect to existing soldier systems. Most prototypes fail on one of those points rather than on the sensor itself, so these requirements belong in the specification before the first print run.
Karl Friedl (Journal of Science and Medicine in Sport, 2018) noted that most commercial physiological monitors “lack the validated algorithms” military use needs and are not open-architected for soldier systems. Use this sequence:
1. Name the decision: RTI Press (2024) puts it plainly: the best wearable “depends on the information you need to make decisions.”
2. Validate against a gold standard: in real-world conditions, including slopes, load and heat.
3. Engineer contact: Dry electrodes need compression, so specify garment fit, electrode location, and stretch together.
4. Budget power and control: Size heaters to the battery pack, with closed-loop control for fixed-resistance designs.
5. Specify washing by use case:BTI’s guidance: hand-wash high-use performance wear; machine-wash only low-use outdoor gear. IEC 63203-204-1:2023 gives a washing durability test method for e-textile products.
6. Plan for integration: The Army’s 2022 SBIR physiological monitoring topic asked for “a modular open system architecture.”
7. Settle documentation and export control early:including quality system scope and ITAR handling.
How Butler Technologies Supports Military and Defense Wearables
Butler Technologies, Inc. (BTI) prints, fabricates and assembles the flexible sensors and heaters used in military wearables, drawing on more than 30 years of custom printed work. Most BTI products are made in Butler, Pennsylvania, from prototype through full-scale production. Capabilities include:
- Printed biometric sensors for ECG, EEG, sEMG and skin impedance, with printed connector tails for integration.
- Flexible heaters in fixed resistance and PTC constructions. BTI’s heater technology warmed the Team USA opening ceremony parkas at PyeongChang 2018.
- Force sensing resistors in ShuntMode and ThruMode, from single-zone sensors to matrix arrays.
- Design, innovation and prototyping, then full-scale production and assembly.
- Quality and compliance: ISO 9001:2015 with Design certification whose scope includes printed electronics, UL and CSA approvals, and ITAR compliance as stated in BTI’s FAQ. See certifications and approvals.
BTI supplies the printed sensor or heater, not Bluetooth modules, garments or software, and refers customers to partners for those. Developing a military wearable? Request a quote to start with a prototype.
Frequently Asked Questions (FAQs)
What is military wearable technology?
Military wearable technology is electronics built into clothing and gear that service members wear, such as heated gloves, biometric sensor shirts, force sensing insoles, and armor liners. It warms the body, monitors physiological strain, maps load, or tracks training and recovery. Printed conductive inks on flexible film keep these components thin, light and able to move with the body.
Are printed heaters safe to use in military clothing?
They can be, when the design controls temperature. PTC heaters have a built-in ceiling of about 80°C. Fixed resistance heaters need a closed-loop controller. For skin contact, BTI recommends staying between 20 and 36°C and insulating anything above 43°C. Test the finished garment with the real battery at worst-case cold before fielding.
Can biometric sensors in military clothing be washed?
Yes, within limits. BTI’s guidance is that printed biometric sensors can be hand-washed for high-use performance wear or machine-washed for low-use outdoor gear. Washability depends on encapsulation and construction, so specify the wash method and cycle count in the requirements, and test against a method such as IEC 63203-204-1:2023 for e-textile washing durability.
How are force sensing resistors used in military boots and body armor?
FSRs printed into insoles, straps, hip belts, and armor liners show where pressure concentrates and how it shifts during movement. Engineers use that data to fit body armor, balance packs, and study gait under load. FSRs are repeatable but less accurate than load cells, so they are best for distribution and trends rather than exact weight.
Is the U.S. military using wearable health monitors today?
Yes. JPEO-CBRND’s WARP program ran its first operational test in November 2024, with fielding slated for fiscal year 2026. USARIEM’s Heat Illness Prevention System has been in development since 2018, and the OHWS program has issued smartwatches and rings to Army personnel, including more than 200 senior officers at the Army War College.